EMT and ENT Fittings
Building MaterialsConduit couplings join two lengths of electrical conduit so you can continue a run through your shop, garage or house. Getting the conduit type and trade size right gives you a joint made for the run, and saves buying a fitting that cannot connect the two ends. Start with the conduit you are joining, then choose the connection style and location rating.
Electrical conduit fittings handle connections throughout a run. A coupling joins two conduit sections; a connector normally terminates conduit at a box or other enclosure. That distinction matters when you are buying parts for several joints and a panel connection on the same job.
An EMT conduit coupling joins two lengths of EMT in a straight run. Compression couplings use a compression nut to grip the conduit ends. Buy this style for an EMT-to-EMT joint where you want a compression connection.
EMT compression couplings come in trade sizes from 1/2 inch up; match the coupling to the conduit’s trade size. A larger coupling is not extra working room; a standard coupling connects the same wiring method and trade size.
| Coupling | Trade size |
|---|---|
| EMT compression coupling | 1/2 inch |
| EMT compression coupling | 1-1/2 inches |
| EMT compression coupling | 1 inch |
| EMT compression coupling | 1-1/4 inches |
| Halex EMT compression conduit coupling, five-pack | 1/2 inch |
For several joints in a 1/2-inch EMT run, buy the Halex five-pack. You get five matching couplings for the same conduit size, which makes it straightforward to buy for repeated connections.
Can conduit compression fittings go outside? Only fittings specifically identified for the location belong there; a compression nut alone does not establish outdoor suitability. For a wet location, buy a wet-location fitting. That matters on Montana shop and pole-barn runs exposed to rain or melting snow.
Both join EMT to EMT; they differ in how they grip and where they can go.
Where the run is wet or outdoors, the deciding question isn’t the style, it’s the rating: use a coupling whose packaging or markings identify it for wet locations. A compression nut doesn’t make a fitting raintight on its own.
Buy an EMT combination coupling when the run changes wiring methods. The coupling must be listed for that particular transition, with both wiring methods identified. A standard EMT conduit coupling connects EMT to EMT; matching the trade size does not turn it into a transition fitting.
That is the distinction to settle before buying for an addition to an existing run. Follow what is on each side of the joint, not just what the new section is made from.
Set-screw couplings clamp two EMT sections together. Buy this style for a matching EMT run where you want a clamp connection. WBC carries Halex 3/4-inch EMT set-screw couplings in a five-pack, handy when a run has several joints.
For several 3/4-inch EMT joints, the Halex 3/4-inch five-pack is the direct pick. For a 1-1/4-inch run, buy the 1-1/4-inch coupling. The connection style is a choice; matching the conduit size is the starting point.
Winter is interior renovation season in Montana. When you are extending a run above an existing ceiling or around framing, look at the room available to tighten each connection before choosing set-screw or compression. Access matters more than habit in a tight corner.
Keep PVC-coated conduit systems separate from this EMT choice: a threaded PVC-coated metal coupling joins coated conduit, while an all-PVC socket coupling joins plain-end rigid PVC conduit. These are different answers to a search for a PVC conduit coupling. For PVC conduit pipe fittings, start by distinguishing rigid PVC from coated metal rather than buying by the word “PVC” alone.
Expansion fittings for PVC conduit serve another job: accommodating movement. Long aboveground PVC runs can expand and contract with temperature changes. Montana’s temperature swings make that a separate selection to address alongside the straight couplings; an ordinary coupling does not take the place of an expansion fitting.
For flexible electrical conduit fittings, start with the tubing type. ENT is electrical nonmetallic tubing, and an ENT flex conduit coupling joins lengths of that tubing. Buy the 1/2-inch ENT coupling for 1/2-inch ENT and the 3/4-inch ENT coupling for 3/4-inch ENT.
That exact match is the reason to choose these couplings. Flexible tubing and rigid PVC need fittings made for their respective wiring methods, even when both are nonmetallic. Likewise, liquid tight conduit fittings for flexible metal conduit must match that wiring method; ENT couplings are the pick for ENT.
For a raceway that needs an offset between boxes or panels, the 1/2-inch and 3/4-inch rigid conduit offset nipples serve that separate job rather than joining two sections in a straight line.
Buy the Halex 1/2-inch compression five-pack for several compression joints in 1/2-inch EMT. Choose the matching 1-, 1-1/4- or 1-1/2-inch compression coupling for those EMT sizes. For set-screw connections, buy the Halex 1/2-inch or 3/4-inch five-pack, or the 1-1/4-inch set-screw coupling. For flexible ENT, buy the 1/2-inch or 3/4-inch ENT coupling to match your tubing.
What are conduit fittings?
Conduit couplings are electrical conduit fittings that join two sections of conduit or tubing. Other fittings handle different jobs: a connector normally ends a run at a box or panel, while an elbow changes its direction. Choose by what the connection needs to do, then match the conduit type and trade size.
What fittings do I need to join EMT conduit?
An EMT coupling joins matching lengths with either a set-screw clamp connection or compression nuts that grip the ends. You can also use these fittings to join a pre-bent section to a straight run. If you’re changing wiring methods at the joint, use a combination fitting listed for that particular transition.
How do I choose a PVC conduit coupling?
Match a PVC conduit coupling to the conduit material as well as its trade size. An all-PVC socket fitting joins plain-end rigid PVC, while a threaded PVC-coated metal fitting belongs to a coated metal conduit system. A center stop positions the ends inside a socket fitting; it doesn’t provide the movement that a separate expansion fitting handles.
What coupling do I need for flexible electrical conduit?
If you’re joining electrical nonmetallic tubing, use an ENT coupling matched to the tubing’s trade size. Flexible metal conduit uses a different wiring method, so matching the size alone won’t make that fitting suitable. Identify the tubing before choosing the connection.
Can conduit compression fittings be used outside?
A conduit compression fitting needs to be specifically identified for the installation conditions; the nut alone doesn’t establish outdoor suitability. For a wet location, choose a fitting identified for wet use. Make that rating part of your selection alongside conduit type and trade size.